Laparascopic products Wound protector
Protetor cirúrgico descartável para feridas
É utilizado em cirurgia endoscópica e de pequenas feridas, e na maioria das operações que requerem retração de incisão. Máxima incisão aberta para proporcionar um campo operatório claro, proteger a incisão de danos e reduzir a poluição da incisão.
CARACTERÍSTICAS
- 360° wound protection and avoid the friction of the incision.
- Type A is made of polyurethane with good biocompatibility; Type B is made of silicone with good biocompatibility.
- Isolating incision site from abdominal viscera to reduce postoperative complication.
Máxima incisão aberta para proporcionar um campo operatório limpo, proteger a incisão contra danos, reduzir o tempo de operação e melhorar a qualidade da cirurgia. - Maintain moisture at the wound margins.
- Uniform tension to reduce tissue damage.
- Prevent tumour transporation on the wound.
- Prevent infection of incision.
- Prevent tissue damage from the wrong surgical operation.

Conector (Hub) Redondo ou Triangular
O cateter de lúmen duplo, triplo e quádruplo tem conector redondo ou triangular para seleção.

Ponta Mole
Soft tip reduces trauma to vessel, minimizing vessel erosion, hemothorax and cardiac tamponade. Single, double, triple and quad lumen is available for choice.

Cabo de ECG (Eletrocardiograma)
Cabo de ECG está disponível.

Marcação de Profundidade
A marcação de profundidade auxilia no posicionamento preciso do cateter venoso central a partir da veia subclávia ou jugular direita ou esquerda.

Radiopacidade
A radiopacidade facilita a confirmação do posicionamento do cateter. As pontas das versões de múltiplos lúmenes são mais radiopacas, facilitando a confirmação do posicionamento da ponta fluoroscópica.

CVC Antibacteriano
The tubing is made from polyurethane which mixed with silver-containing zirconium phosphate at nanometer level, when the catheter is placed into the body, Ag+ will be released to inhibit bacteria growing.
Standard Needle Free Connector
1. Transparent housing material: Polycarbonate or Copolyester
2. Large internal space is suitable to use with high flow catheter, such as hemodialysis catheter.
3. Metal-free & MRI-compatible & Latex-free & DEHP free & Anti-esterificatio.
4. High quality silicone valve ensure multiple insertion without leakage.
5. Excellent air-tight design keeps the connector out of air, fluid and foreign material.
6. Small size and transparent housing make the patient more comfortable.
7. ISO 10993 & ISO 80369 compliant.
8. technical data:
– Priming Volume: 0.09ml.
– Perfect flowing rate: 350 ml/min under one meter water pressure, tested by Baihe Technical Team.
– Dead space: 0.001ml
– Activation: 300 times/72 hours
– Pressure resistance 100PSI
ESPECIFICAÇÕES
| Número de peças | Dimensões | GW | |
| Unit Box | 15 | 14.5*24. 5*10cm | 0,15 |
| Caixa Intermédia | 60 | 44*28*15.5cm | 0,5 |
| Caixa de Expedição | 300 | 62*36*59cm | 1 |
| Model | Especificações/Especificaciones | Inner Diam. (mm) | Outer Diam. (mm) | Channel Length (mm) | |
| A | A-60 | 70 | 60 | 60 | 150 |
| A | A-80 | 90 | 80 | 80 | 150 |
| A | A-120 | 130 | 120 | 120 | 250 |
| A | A-150 | 160 | 150 | 150 | 250 |
| A | A-180 | 190 | 180 | 180 | 250 |
| A | A-220 | 230 | 220 | 220 | 250 |
| B | B-40 | 30 | 40 | 15 | 30 |
| B | B-50 | 40 | 50 | 25 | 30 |
| B | B-70 | 70 | 70 | 35 | 40 |
| B | B-120 | 100 | 120 | 60 | 30 |
DOCUMENTS