Laparascopic products Wound protector
Einweg-Wundschutz für chirurgische Eingriffe
Es wird bei endoskopischen Eingriffen, Operationen mit kleinen Wunden und den meisten Operationen, die eine Inzisionsretraktion erfordern, eingesetzt. Maximale Inzision für ein klares Operationsfeld, Schutz der Inzision vor Beschädigungen und Reduzierung der Inzisionsverschmutzung.
MERKMALE
- 360° wound protection and avoid the friction of the incision.
- Type A is made of polyurethane with good biocompatibility; Type B is made of silicone with good biocompatibility.
- Isolating incision site from abdominal viscera to reduce postoperative complication.
Maximale Inzision für ein klares Operationsfeld, Schutz der Inzision vor Beschädigungen, Verkürzung der Operationszeit und Verbesserung der Operationsqualität. - Maintain moisture at the wound margins.
- Uniform tension to reduce tissue damage.
- Prevent tumour transporation on the wound.
- Prevent infection of incision.
- Prevent tissue damage from the wrong surgical operation.

Runde oder dreieckige Nabe
Doppel-, Dreifach- und Vierfachlumenkatheter verfügen wahlweise über einen runden oder dreieckigen Konnektor.

Weiche Spitze
Soft tip reduces trauma to vessel, minimizing vessel erosion, hemothorax and cardiac tamponade. Single, double, triple and quad lumen is available for choice.

EKG-Kabel
Ein EKG-Kabel ist verfügbar.

Tiefenwirkung
Die Tiefenmarkierung erleichtert die genaue Platzierung eines zentralen Venenkatheters über die rechte oder linke Vena subclavia oder Vena jugularis.

Röntgendichte
Die Röntgensichtbarkeit erleichtert die Bestätigung der Katheterlage. Die Spitzen der Mehrlumenversion sind röntgendichter, was die Bestätigung der Lage der Durchleuchtungsspitze vereinfacht.

Antibakterieller zentralvenöser Katheter
The tubing is made from polyurethane which mixed with silver-containing zirconium phosphate at nanometer level, when the catheter is placed into the body, Ag+ will be released to inhibit bacteria growing.
Standard Needle Free Connector
1. Transparent housing material: Polycarbonate or Copolyester
2. Large internal space is suitable to use with high flow catheter, such as hemodialysis catheter.
3. Metal-free & MRI-compatible & Latex-free & DEHP free & Anti-esterificatio.
4. High quality silicone valve ensure multiple insertion without leakage.
5. Excellent air-tight design keeps the connector out of air, fluid and foreign material.
6. Small size and transparent housing make the patient more comfortable.
7. ISO 10993 & ISO 80369 compliant.
8. technical data:
– Priming Volume: 0.09ml.
– Perfect flowing rate: 350 ml/min under one meter water pressure, tested by Baihe Technical Team.
– Dead space: 0.001ml
– Activation: 300 times/72 hours
– Pressure resistance 100PSI
SPEZIFIKATIONEN
| Anzahl der Teile | Abmessungen | GW | |
| Unit Box | 15 | 14.5*24. 5*10cm | 0,15 |
| Mittlerer Karton | 60 | 44*28*15.5cm | 0,5 |
| Versandkarton | 300 | 62*36*59cm | 1 |
| Model | Spezifikation | Inner Diam. (mm) | Outer Diam. (mm) | Channel Length (mm) | |
| A | A-60 | 70 | 60 | 60 | 150 |
| A | A-80 | 90 | 80 | 80 | 150 |
| A | A-120 | 130 | 120 | 120 | 250 |
| A | A-150 | 160 | 150 | 150 | 250 |
| A | A-180 | 190 | 180 | 180 | 250 |
| A | A-220 | 230 | 220 | 220 | 250 |
| B | B-40 | 30 | 40 | 15 | 30 |
| B | B-50 | 40 | 50 | 25 | 30 |
| B | B-70 | 70 | 70 | 35 | 40 |
| B | B-120 | 100 | 120 | 60 | 30 |
DOCUMENTS